Formula
Short-form torque is K times nominal diameter times clamp load. In inch units that product is inch-pounds. Fastenal says torque is only an indirect indication of tension, because friction in the threads and under the head is inside K. Lubrication lowers K, so the same published dry torque puts more tension in the bolt. Use the K for the finish you have.
T = K × D × F
As = 0.7854 × (D − 0.9743 / n)²
As = 0.7854 × (d − 0.9382 × P)²
The inch area is the ASME B1.1 expression printed by Engineers Edge. The metric expression is the one that reproduces the nominal stress areas in ISO 898-1:2013 Tables 5 and 6. Section 9.1.6.1, which the standard points to for that calculation, was not in the preview that was read. Proof stress is the Portland Bolt printing of the SAE J429 table: Grade 2 is 55,000 psi through 3/4 in and 33,000 psi over that, and a Grade 2 bolt longer than 6 in uses 33,000 psi. Grade 5 is 85,000 psi through 1 in and 74,000 psi over 1 in. Grade 8 is 120,000 psi through 1-1/2 in. ISO 898-1:2013 class 8.8 is 580 MPa through 16 mm and 600 MPa above that. The M16 and M18 proof-load rows match that split. Class 10.9 is 830 MPa. Class 12.9 is 970 MPa.
Fastenal’s torque-tension chart, revision 3-6-09, calculates clamp load as 75 percent of proof and uses K of 0.20 plain and dry, 0.17 zinc plated and dry, and 0.15 lubricated. That 75 percent is the default here, and it stops at 90. The IFI bulletin of February 2008, with K values from DIN 946, prints plain 0.20, copper anti-seize 0.13, machine oil 0.21, and zinc-and-clear 0.22. A moly paste was not given a number in that bulletin, so none is offered. IFI also describes a separate test method that targets 75 percent of yield. This page uses Fastenal’s 75 percent of proof, not that yield test.
Worked examples
1/2-13 Grade 5, 75 percent, K 0.20. Area 0.1419 in². Clamp load 9,046 lbf. Torque 904.6 in-lb, 75.4 ft-lb. 3/8-16 Grade 8, 75 percent, K 0.15. Area 0.07749 in². Clamp load 6,974 lbf. Torque 32.7 ft-lb.
M10×1.5 class 8.8, 75 percent of 580 MPa, K 0.20. Area 57.99 mm². Clamp load 25.23 kN. Torque 50.5 N·m. Direct: 0.625 in, 10,000 lbf, K 0.20. 1,250 in-lb, 104.2 ft-lb. Reverse: 1/2 in, 75.38 ft-lb, K 0.20. 9,046 lbf.
Reference
| UNC | Grade 5 | Grade 8 |
|---|---|---|
| 1/4-20 UNC | 8.5 | 11.9 |
| 5/16-18 UNC | 17.4 | 24.6 |
| 3/8-16 UNC | 30.9 | 43.6 |
| 7/16-14 UNC | 49.4 | 69.8 |
| 1/2-13 UNC | 75.4 | 106.4 |
| 9/16-12 UNC | 108.7 | 153.5 |
| 5/8-11 UNC | 150.1 | 211.9 |
| 3/4-10 UNC | 266.5 | 376.3 |
| 7/8-9 UNC | 429.3 | 606.0 |
| 1-8 UNC | 643.6 | 908.6 |
Questions
How do you calculate bolt torque?
Torque is K times nominal diameter times clamp load. K is the nut factor. For a grade, clamp load is a percent of proof load, and proof load is proof stress times tensile stress area. Every figure on this page is that K-factor estimate.
What is the K factor, or nut factor?
Fastenal’s chart uses 0.20 for plain and dry, 0.17 for zinc plated and dry, and 0.15 for lubricated. The IFI February 2008 bulletin prints 0.20 for plain, 0.13 for copper anti-seize, and 0.21 for machine oil. K is not one material property. It is the joint that day.
What torque for a 1/2 inch grade 8 bolt?
At 75 percent of proof and K 0.20, 1/2-13 Grade 8 is the same arithmetic as Grade 5 with 120,000 psi instead of 85,000 psi. The reference table is that dry estimate. A wheel, a head, or a suspension joint uses the published spec, not this row.
Does lubrication change torque?
Yes. The same clamp load needs less torque when K drops. Using a dry torque on an oiled or anti-seized bolt raises the preload. Fastenal’s lubricated column is 0.15. IFI machine oil is 0.21. Match the K to the finish you actually have.
What is bolt preload?
Preload is the clamp load, the tension in the bolt. Torque is only an indirect way to get there. Fastenal says torque is only an indirect indication of tension. Proof load is the load the standard uses. Yield and tensile are higher.
How much should I torque a bolt?
The manufacturer and the service manual override this estimate. Critical joints, including wheels, heads, suspension, structural joints, and pressure joints, use the published spec. This page does not keep a wheel-lug table or an engine table.
What is the difference between torque and clamp load?
Clamp load is the force. Torque is K times diameter times that force. Most of the torque is friction, which is why K dominates. A torque-angle or stretch method is the better check on a critical joint. This page does not run that method.
Sources
- Portland Bolt, “J429 Strength Requirements,” the mechanical-properties table: Grade 2, Grade 5, and Grade 8 full-size proof loads, including the step-downs and the note that Grade 2 bolts longer than 6 in follow Grade 1.
- ISO 898-1:2013 Table 3, as printed in the Kova extract and in the ISO sample: proof stress 580 MPa for class 8.8 through 16 mm, 600 MPa above 16 mm, 830 MPa for 10.9, 970 MPa for 12.9. Tables 5 and 6 supply the nominal stress areas used as the check.
- Engineers Edge, thread tensile stress area: ASME B1.1 As = 0.7854 [D − 0.9743/(1/P)]².
- Fastenal, Torque-Tension Relationship for A307A, Grade 5, 8 and 9, revision 3-6-09. T = KDF. K = 0.20 plain and dry, 0.17 zinc plated and dry, 0.15 lubricated. Clamp load at 75 percent of proof. Torque is only an indirect indication of tension.
- Industrial Fasteners Institute, “Fastener Tightening,” February 2008. K from DIN 946, including plain 0.20, copper-based antiseize 0.13, and machine oil 0.21. The bulletin also describes a yield-torque test aimed at 75 percent of yield.