Plumbing

Septic Tank Size Calculator

Typical septic tank gallons from the 2025 CPC Appendix H bedroom table and the flow formula. The health department sets the minimum. No drain-field size.

Checked 2026-11-18. The answer below is computed on this page.

Tank

Typical sizing only. Septic systems are permitted by your state or county health department, whose rules set the actual minimum.

gal/day

Editable planning assumption. Not a number from the bedroom table. Local rules differ.

ft
ft
ft

To the outlet invert, not the tank top.

ft
ft

Common tank

1,000 gal

Bedroom table
1,000 gal
Flow formula
675 gal
Rectangle
—
Cylinder
—

Typical sizing only. Septic systems are permitted by your state or county health department, whose rules set the actual minimum.

Typical sizing only. No drain field is calculated. Inspect about every 3 years and pump typically every 3 to 5 years, per EPA's care page. A particular tank depends on the sludge and scum.

Formula

The single-family column of Table H 201.1(1) in the 2025 California Plumbing Code Appendix H, which uses the Uniform Plumbing Code appendix numbering, lists 750 gallons for 1 or 2 bedrooms, 1,000 for 3, 1,200 for 4, and 1,500 for 5 or 6. Note 1 adds 150 gallons for each extra bedroom. This page does not extend that note into a recommendation past 6 bedrooms. Seven or more bedrooms use the flow formula only, with that note named so you can take it to the health department.

V = 1.5 × Q when Q is at most 1,500 gal/day
V = 1,125 + 0.75 × Q when Q is above 1,500 gal/day

Those two lines are note 1 on Table H 201.1(4) of the same appendix: flow times 1.5 up to 1,500 gallons per day, and flow times 0.75 plus 1,125 above that. The recommendation is the larger of the bedroom table and that volume, then the next common tank of 750, 1,000, 1,250, 1,500, 2,000, 2,500, or 3,000 gallons. Above 3,000 the step is 500 gallons. A result that lands on a listed size stays there. Note 4 says the bedroom-table sizes already include sludge storage and a domestic food-waste disposer without a further increase. The 50 percent switch is a local-rule option, not that note.

One hundred fifty gallons per bedroom per day is an editable planning assumption. It is not printed in the bedroom table. Nevada Division of Environmental Protection WTS-22, revision 5, 2017, says the tank shall be 1,000 gallons minimum and then uses the same two flow lines. That is one state's design sheet, not a national floor. A rectangle is length times width times liquid depth. A horizontal cylinder is the circle times the liquid length. Gallons are cubic feet times 7.48052. Liquid depth stops at the outlet invert. Appendix H also sizes leaching area. This page does not. The health department and a perc test do.

Worked examples

3 bedrooms at 150 gallons per day. Flow 450, volume 675. Table 1,000. Recommend 1,000. The 50 percent switch makes 1,500. 4 bedrooms. Flow 600, volume 900. Table 1,200. Recommend 1,250. 6 bedrooms. Flow 900, volume 1,350. Table 1,500. Recommend 1,500.

1,000 gallons per day. 1,500 gallons. 2,000 gallons per day. 1,125 + 1,500 = 2,625, so a 3,000 gallon tank. 8 × 5 × 4 ft liquid. 1,196.9 gallons. 6 ft diameter by 8 ft. 1,692.1 gallons. 5 ft diameter by 10 ft. 1,468.8 gallons.

Reference

Bedroom table and the flow formula at 150 gallons per bedroom per day. Generated by the same functions. Not a permit.
BedroomsTableFlow formula
1750 gal225 gal
2750 gal450 gal
31,000 gal675 gal
41,200 gal900 gal
51,500 gal1,125 gal
61,500 gal1,350 gal

EPA's page How to Care for Your Septic System says an average household system should be inspected at least every three years, and that household tanks are typically pumped every three to five years. Household size, wastewater, solids, and tank size change that interval. This page does not compute it.

Questions

What size septic tank do I need for a 3 bedroom house?

Table H 201.1(1) in the 2025 California Plumbing Code Appendix H lists 1,000 gallons for 3 bedrooms. At 150 gallons per bedroom per day the flow formula is 675 gallons, so the table governs. That 150 is a planning assumption, not a figure in the bedroom table. Your health department sets the minimum.

How many gallons is a standard septic tank?

The single-family column lists 750 gallons for 1 or 2 bedrooms, 1,000 for 3, 1,200 for 4, and 1,500 for 5 or 6. Purchased tanks often step 750, 1,000, 1,250, 1,500, then 500-gallon jumps. A 1,200 gallon table result rounds to a 1,250 gallon tank on this page.

How big is a 1,000 gallon septic tank?

The inside liquid dimensions vary by the manufacturer. Eight by five by four feet of liquid is about 1,197 gallons. Liquid depth is to the outlet invert, not the top of the tank.

Does a garbage disposal need a bigger septic tank?

Note 4 on that bedroom table says the listed sizes already include a domestic food-waste disposer without a further increase. Some local rules still add capacity. The +50% switch is off unless you turn it on, and it is labelled as a local check, not as the UPC.

How often should a septic tank be pumped?

EPA's care page says an average household system should be inspected at least every three years, and that household tanks are typically pumped every three to five years. Sludge and scum depth decide a particular tank. This page does not compute a pump-out date.

Can I calculate drain field size here?

No. Appendix H also has soil and leaching tables. This page does not use them. A perc test and the health department size the field.

Who sets septic tank size rules?

The state or county health department. The code tables here are typical sizing from the appendix that was read. They are not a permit.

Sources

  • 2025 California Plumbing Code, Appendix H, Table H 201.1(1) and the sizing notes on Table H 201.1(4). Single-family gallons by bedroom, and flow times 1.5 or flow times 0.75 plus 1,125. Note 4 includes a domestic food-waste disposer in the table sizes. Leaching tables in the same appendix are not used here.
  • Nevada Division of Environmental Protection, WTS-22, revision 5, 2017. One state sheet: 1,000 gallon minimum, then the same two flow lines.
  • U.S. EPA, How to Care for Your Septic System. Inspect at least every three years. Pump typically every three to five years.
  • 1 cubic foot = 7.48052 US gallons, the factor already on the tank volume page.