Formula
Recommended gas-heater output is the pool surface in square feet times the temperature rise in °F times 12. The rise is the desired water temperature minus the average air temperature of the coldest month you swim. The U.S. Department of Energy Energy Saver article says that formula is based on a 1° to 1¼°F rise per hour and a 3½ mph average wind at the water. It says to multiply by 1.5 for a 1½°F pace and by 2 for 2°F. This page uses the base formula. Wind, low humidity, and cool nights need a larger heater, and the article says a trained pool professional should size the heater.
output = area × rise × 12
input = output ÷ efficiency
BTU = gallons × 8.34 × ΔT
hours = BTU ÷ output
Gas heaters in the article are rated by output, from 75,000 to 450,000 BTU. Nameplates are often input, so this page also divides by the efficiency you type. Heat to raise the water is gallons times 8.34 pounds per gallon times the rise. One kilowatt-hour is 3,412.14 BTU. Electric output is kilowatts times that factor. The hours are a minimum with no evaporation, wind, or uncovered surface. A cover is noted and does not change the number.
Worked examples
16 × 32 ft, 82°F water, 62°F air. 512 ft² and a 20°F rise. Output 122,880 BTU/h. At 84 percent, input 146,286 BTU/h. 24 ft round, 15°F rise. 452.39 ft² and 81,430 BTU/h.
20,000 gallons from 70°F to 80°F. 1,668,000 BTU, 488.8 kWh. Gas at 200,000 BTU/h input and 84 percent is 9.93 hours. A 100,000 BTU/h heat pump is 16.68 hours. An 11 kW electric heater is 37,533.5 BTU/h and 44.4 hours. 10 × 5 m with an 18°F rise is about 116,250 BTU/h.
Reference
Surface area drives the size because that is where the pool loses heat. Gallons drive only the heat-up sum. The heat-pump page in the same Energy Saver set uses the same area formula, lists 3.5 hp / 75,000 BTU, 5 hp / 100,000 BTU, and 6 hp / 125,000 BTU, and says the units work efficiently above about 45–50°F. The 2012 text says manufacturers often quote COP at 80°F outside and 80°F water, with COPs of about 3 to 7. Output falls as the air cools. Gas piping, venting, and electric wiring are not calculated here. A heater also needs the minimum flow its maker lists. That flow, from the pool volume, is the pool pump run time calculator.
Questions
What size pool heater do I need?
For an outdoor pool, the Energy Saver article sizes output as surface area in square feet times the temperature rise times 12. The rise is the water temperature you want minus the average air temperature of the coldest month you swim. A trained pool professional still does the real selection.
How many BTU to heat a pool?
A 16 by 32 foot pool is 512 square feet. A 20°F rise is 512 × 20 × 12 = 122,880 BTU per hour of output. At 84 percent efficiency the input is about 146,286 BTU per hour. The 84 percent figure is one you can edit. The article says the efficiency is on the nameplate.
How long does it take to heat a pool?
Gallons times 8.34 pounds per gallon times the rise, divided by the heater’s output. Twenty thousand gallons from 70°F to 80°F is 1,668,000 BTU. A 200,000 BTU/h gas heater at 84 percent delivers 168,000 BTU/h, about 9.93 hours if no heat is lost. A real pool takes longer.
Is a heat pump or a gas heater better?
The Energy Saver pages say gas heats quickly and holds a temperature in any weather, and that heat pumps cost less to run when the air stays above about 45–50°F. Heat-pump output falls as the air cools. This page does not pick one.
What size heat pump for a 15,000 gallon pool?
Gallons do not set the size. Surface area does. A 15 by 30 foot pool is 450 square feet. At a 20°F rise the same formula is 108,000 BTU/h of output. The article’s example heat-pump sizes are 75,000, 100,000, and 125,000 BTU. Confirm the rating conditions. The copy read here tests COP at 80°F air and 80°F water.
Does a pool cover help?
The Energy Saver cost tables show a covered pool costing much less to heat than the same pool uncovered, for the cities they list. Evaporation is the loss a cover is aimed at. This page does not multiply by a cover factor. The cover is a note, not a fudge.
Sources
- U.S. Department of Energy, Energy Saver, “Selecting a Gas Pool Heater,” as published on energy.gov and read from the Energy Saver text. Output = pool area × temperature rise × 12, based on 1° to 1¼°F per hour and a 3½ mph wind. Gas heaters rated by output, 75,000 to 450,000 BTU. Efficiency is output divided by input. Some models 89–95 percent.
- U.S. Department of Energy, Energy Saver, “Heat Pump Swimming Pool Heaters,” May 29, 2012, in the same Energy Saver set. Same sizing formula. Efficient above about 45–50°F. Standard sizes 75,000, 100,000, and 125,000 BTU. COP commonly quoted at 80°F air and 80°F water.
- 8.34 pounds per gallon is the factor already on the pool volume page. 3,412.14 BTU per kWh is the factor already on the furnace and heat-pump pages.