Formula
Hours for one turnover are gallons divided by gallons per minute, then by 60. The flow for a chosen turnover time is gallons divided by hours, then by 60. Daily hours are that turnover time times the number of turnovers. More than 24 hours means the pump flow is too small for that target.
hours = gallons / (GPM × 60)
TDH = psi × 2.31 + inHg × 1.13
ft/s = GPM / (448.83 × area)
Hayward's 2026 buyer's guide uses 2.31 feet of water per psi and 1.13 feet per inch of mercury. It recommends a maximum of 6 or 8 ft/s on suction lines and 10 ft/s on return lines, and says to check local regulations. This page flags suction above 6 ft/s and return above 8 ft/s. The pipe areas use Schedule 40 inside diameters of 1.610, 2.067, 2.469, and 3.068 inches. ANSI/APSP/ICC-15 was not read, so it is not cited.
Affinity laws used here are the ideal ones: flow scales with speed, and power scales with the cube of speed. The same daily volume then takes the inverse of the speed ratio in hours. Hayward notes that actual variable-speed savings vary with the plumbing, the hours, and the rate. The cubic result is labelled an estimate. One turnover a day is the starting point on this page. Circulation is the water moving. Filtration is what the filter removes while it moves. A chlorinator and a heater need the minimum flow their labels list, and a chemical timing still follows the product label. Run the pump while the pool is in use, after a chemical addition, and after a storm. The clock time is yours.
Worked examples
20,000 gallons in 8 hours. 41.67 GPM. 20,000 gallons at 50 GPM. 6.67 hours, 6 hours 40 minutes. 15,000 gallons at 40 GPM. 6.25 hours. 15,000 gallons in 6 hours. 41.67 GPM. 15 psi and 5 inHg. 40.3 feet of head.
2 inch Schedule 40. 62.8 GPM at 6 ft/s and 83.7 GPM at 8 ft/s. 1.5 inch. 38.1 and 50.8 GPM. 1.5 kW, 8 hours, $0.17 per kWh. $2.04 a day and $61.20 for 30 days. 3,450 rpm to 1,725 rpm. Flow halves, power falls to one eighth, hours double, and daily energy falls from 12 kWh to 3 kWh on the ideal law.
Reference
| Pipe | 6 ft/s | 8 ft/s |
|---|---|---|
| 1.5 in | 38.1 GPM | 50.8 GPM |
| 2 in | 62.8 GPM | 83.7 GPM |
| 2.5 in | 89.5 GPM | 119.4 GPM |
| 3 in | 138.3 GPM | 184.3 GPM |
Suction outlets need covers and a drain arrangement that meets the Virginia Graeme Baker Act. This page does not check a drain cover. Without gauges, Hayward lists suction-side factors for a short 2 inch line: about 4.5 to 5.5 feet for a 3/4 HP pump, 7 to 9 for 1 HP, 10 to 12.5 for 1-1/2 HP, and 13.5 to 16 for 2 HP. Those are not a full total dynamic head. Add the filter pressure when you have it.
Questions
How long should I run my pool pump?
Hours per turnover are gallons divided by flow in gallons per minute, then by 60. A 20,000 gallon pool at 50 GPM turns over in 6.67 hours. One turnover a day is this page's starting point. Local rules set the minimum. Chemical timing follows the product label.
What is a good turnover rate?
Turnover time is how long it takes to move the pool volume through the system once. Hayward's 2026 guide tells you to check local regulations for the minimum. This page starts at one turnover and will go from 1 to 4.
What size pump do I need for a 20,000 gallon pool?
An 8 hour turnover needs 41.67 GPM. That is the flow, not a pump model. The pump also has to meet the head from the gauges and stay inside the pipe velocity.
How do I calculate total dynamic head?
Hayward's 2026 buyer's guide multiplies the filter pressure in psi by 2.31 and the suction vacuum in inches of mercury by 1.13, then adds them. 15 psi and 5 inHg is 40.3 feet. Without a vacuum gauge the suction side is missing.
Is it cheaper to run a variable-speed pump longer?
On the ideal affinity laws, half speed is half the flow and one eighth of the power. The same daily volume takes twice as long and uses one quarter of the energy. Hayward says real savings vary with the plumbing, the hours, and the rate. This result is labelled an estimate.
Can a pool pump be too big?
A flow that pushes suction pipe over 6 ft/s, or return pipe over 8 ft/s, is flagged. Hayward also lists 10 ft/s as a return figure and says to check local rules. More flow is not automatically better.
Should I run the pump at night?
Run it when the pool is in use, after you add a chemical (follow that product's label), and after a storm. A variable-speed pump can spread the same volume across more hours. This page does not pick a clock time.
Sources
- Hayward, 2026 Buyer's Guide, hydraulics section. Filter psi times 2.31, vacuum inches of mercury times 1.13. Maximum recommended velocity 6 or 8 ft/s on suction and 10 ft/s on return. Check local regulations. Variable-speed savings vary with plumbing, hours, and the electric rate.