Solar

Battery Charge Time Calculator

Hours to charge from a starting state of charge. Coulombic efficiency from Battery University. Manufacturer limits come first. No voltage setpoint.

Checked 2026-11-21. The answer below is computed on this page.

Battery and charger

An estimate. The battery and charger manufacturer’s maximum charge current and voltage come first. This page does not set a voltage.

Ah
%

BU-808c coulombic efficiency: lead-acid about 90%, Li-ion above 99% at a moderate current. Edit it. AGM is not a separate number there.

%
%
A
W

Leave at 0 to skip solar days.

%

86% is one minus the 14% PVWatts loss used on the solar calculator. Edit it.

Charge time, estimate

8 h 53 min

Hours
8.889 h
To add
80 Ah
C-rate
0.10C
Solar days
—

Follow the battery and charger manufacturer’s maximum charge current and voltage. No voltage setpoint is calculated.

Formula

Amp-hours to add are capacity times the change in state of charge. Watt-hours are that figure times nominal voltage, or the watt-hour capacity times the same change. Hours are the energy to add, divided by charger power, divided by coulombic efficiency. Watts become amps by dividing by nominal voltage when the capacity is in amp-hours. In watt-hour mode the charger watts are used directly.

Ah to add = Ah × (target − start) ÷ 100
hours = Ah to add ÷ (amps × efficiency)
C-rate = amps ÷ Ah

BU-808c (4 November 2021) puts lead-acid coulombic efficiency at about 90 percent and says lithium-ion exceeds 99 percent at a moderate current and cool temperature. Those are the presets. AGM and gel are not given a separate figure, so they start at the same 90 percent. Energy efficiency is a different, lower number in that article, about 97 percent for lithium-ion at 0.5C. This clock uses coulombic efficiency because the inputs are amp-hours and amps. Edit the percent.

BU-403 says the constant-current stage of a lead-acid charge reaches about 70 percent and the rest is a slower topping charge. The constant-current portion takes roughly half the time in that description. When the chemistry is lead-acid or AGM and the target is above 80 percent, the result says the real time to 100 percent is longer. No taper multiplier is applied. BU-403 also says manufacturers recommend a charge rate around 0.3C. A lithium maximum is the battery maker’s, and it is not printed here. Lead-acid charging gives off hydrogen. BU-403 says to charge in a ventilated area.

Solar days are the watt-hours still needed, divided by efficiency, divided by panel watts times peak sun hours times controller efficiency. The 86 percent controller start is one minus the 14 percent PVWatts loss on the solar calculator. Peak sun hours are the same planning buttons as that page, not a live irradiance lookup.

Worked examples

100 Ah, 12 V, lead-acid, 20 to 100 percent, 10 A, 85 percent. 80 Ah. 9.412 h, 9 h 25 min. 0.10C. 100 Ah, 12.8 V, LiFePO4, 0 to 100 percent, 20 A, 95 percent. 5.263 h, 5 h 16 min. 0.20C.

1,000 Wh, 50 to 100 percent, 200 W, 90 percent. 500 Wh. 2.778 h, 2 h 47 min. 48 Ah, 12 V, AGM, 20 to 100 percent, 5 A, 85 percent. 9.035 h, 9 h 2 min. 100 Ah, 12 V, 120 W. That is 10 A, and at 85 percent it matches the first case, 9.412 h.

Reference

Hours to take a 100 Ah battery from 20 to 100 percent. Lead-acid uses the 90 percent BU-808c coulombic figure. LiFePO4 uses 99 percent. No taper is added.
AmpsLead-acid, 90%LiFePO4, 99%
5 A17 h 47 min16 h 10 min
10 A8 h 53 min8 h 5 min
20 A4 h 27 min4 h 2 min
30 A2 h 58 min2 h 42 min
50 A1 h 47 min1 h 37 min

Questions

How long does it take to charge a 100 Ah battery?

It depends on the current and the coulombic efficiency. At 10 A and 85 percent, 80 Ah takes 9.412 hours, 9 hours 25 minutes. The 90 percent lead-acid default from Battery University is a different number. The manufacturer’s max current still comes first.

How do you calculate battery charging time?

Amp-hours to add, divided by charger amps, divided by efficiency. Watt-hours use the same idea with watts. The result is a straight line. It does not add a lead-acid taper.

How long to charge a car battery at 10 amps?

A 48 Ah AGM battery from 20 to 100 percent at 5 A and 85 percent is 9.035 hours. At 10 A the same arithmetic is half of that only if the charger really holds 10 A. A car battery’s accepted current is the maker’s limit, and this page does not publish a voltage setpoint.

How long does a LiFePO4 battery take to charge?

100 Ah from empty at 20 A and 95 percent is 5.263 hours, 5 hours 16 minutes, 0.20C. BU-808c puts lithium-ion coulombic efficiency above 99 percent at a moderate current. The 95 percent figure is one you can type. The pack’s maximum charge current is the manufacturer’s.

What size charger do I need for a 100 Ah battery?

C-rate is charger amps divided by amp-hours. BU-403 says manufacturers recommend about 0.3C for lead-acid, and that a higher rate is discussed only while the current is moderated toward full charge. Lithium follows the battery maker’s maximum. This page does not pick a charger model.

Why does the last 20 percent take longer?

BU-403 says a lead-acid constant-current stage reaches about 70 percent, and the remaining charge is a slower topping stage. When the target is above 80 percent this page says the linear estimate is short of that real time. It does not multiply the hours by an invented taper factor.

Can I charge a battery with a solar panel directly?

Use a charge controller. Days here are watt-hours still needed, divided by panel watts, peak sun hours, controller efficiency, and the battery efficiency. The solar calculator sizes an array. This page only times a charge.

Sources

  • Battery University BU-808c, Coulombic and Energy Efficiency with the Battery, updated 4 November 2021. Lead-acid coulombic efficiency about 90 percent. Lithium-ion above 99 percent at a moderate current and cool temperature. Lithium-ion energy efficiency about 97 percent at 0.5C.
  • Battery University BU-403, Charging Lead Acid, updated 8 December 2023. Three stages. Constant current to about 70 percent, then a slower topping charge. Manufacturers recommend about 0.3C. Charge in a ventilated area because of hydrogen.
  • The solar calculator on this site: system loss starts at 14 percent, the PVWatts historical default. Peak sun hours are planning averages, not a station lookup.

Related calculators